TX Screwdriver for TORX screws 1000V

  • For Torx screws
  • The ergonomic design and pronounced quick driving area makes it possible to work quickly without getting tired thanks to the optimum and hand-friendly power transmission
  • Insulation according to DIN EN/IEC 60900
  • Blades made of molybdenum vanadium steel
  • Blades hardened and blackened with injected insulation
Grouped product items
Article    
2039-T20-100 190 100 90 20 1000V Design 50 12 40 03758 20390 3  
2039-T25-125 215 125 90 25 1000V Design 60 12 40 03758 20391 0  
2039-T27-125 225 125 100 27 1000V Design 80 12 40 03758 20393 4  
2039-T30-150 250 150 100 30 1000V Design 100 1 40 03758 20392 7  
Loading...
nws_i_elektrische-spannung.png

For working at or close to electrical parts please observe safety regulations for electrical works and additional national safety regulations.
Check that insulation is not damaged each time before using the tools. Do not use damaged tools anymore. Keep your safety tools clean and dry. Ensure that the workplace where you are working on live equipment is clean and tidy. Use protective clothing and safety equipment (eg. safety gloves, cover clothes and safety sleeves), especially when working in narrow areas.
Electrical work (worked carried out on electrical devices an systems) must be either conducted by a qualified electrician or supervised and checked by one.

Sicherheitswerkzeuge.png

Better safe than sorry.
Electricians put their faith in their tools daily. Electricity is always a potential hazard. Whether they are cutting cables to size, fitting socket outlets or configuring switch cabinets, they need tools they can rely on without fail. When an electrician picks up a set of VDE tools made by NWS, he or she is handling quality tools subjected to stringent testing for practical, hands-on applications in electrical jobs. This is, after all, what professional working, health & safety are all about.

nws_i_1000V.png

Safety testing method according to IEC 60900
• Visual check and check of measurements: single check of the lettering on the basis tool as well as on the insulation.
• Check of resistance under hot and cold conditions: under normal temperatures of the surroundings (23° C) as well as under low temperatures (-25° C) on three different positions easy to hurt.
• Single voltage check: check of the electrical insulating characteristics by putting on a 10 KV voltage in a water bath for three minutes and measuring the deflecting electricity.
• Pressure check - check of puncture: storage of tools in a warming box for 2 hours at the temperature of 70° C putting on a 5 KV Voltage for three minutes and raising a power of 20 N on the insulation.
• Check of the adhesive power of the insulation: storage of tools in a warming box for 168 h at a temperature of 70° C raising a power of 500 N for three minutes on the area between the conductive part and the insulation.
• Check of fire risk: raising a flame on the insulation for 10 seconds.