Self-adjusting Stripping Pliers VDE

  • For stripping solid, stranded or finely stranded conductors with standard insulation
  • For single and stranded conductors
  • With opening spring and catch
  • The precise adjustment makes it easier to remove the multiple insulation layers of solar cables
  • Adjustable stripping length
  • Insulation according to DIN EN/IEC 60900
  • Made of reinforced fibreglass plastic
  704-VDE-180-SB
Length - mm180
Length - in7
Cable - Al + Cu multi-wired conductor single and stranded conductor - cutting capacity - Ø mm2
Stripping length - mm5 - 12
Stripping capacities - mm²0,2 - 6
With opening springWith opening spring
DesignVDE Design
Weight - g115
Length including self-service packaging - mm270
Width including self-service packaging - mm100
Height including self-service packaging - mm28
Weight self-service packaging - g10
Packing unit6
Barcode40 03758 60403 8
nws_i_elektrische-spannung.png

For working at or close to electrical parts please observe safety regulations for electrical works and additional national safety regulations.
Check that insulation is not damaged each time before using the tools. Do not use damaged tools anymore. Keep your safety tools clean and dry. Ensure that the workplace where you are working on live equipment is clean and tidy. Use protective clothing and safety equipment (eg. safety gloves, cover clothes and safety sleeves), especially when working in narrow areas.
Electrical work (worked carried out on electrical devices an systems) must be either conducted by a qualified electrician or supervised and checked by one.

Self-adjusting wire strippers
Self-adjusting wire strippers eliminate the annoying task of presetting and adjusting each wire gauge, and reduce to a minimum the risk of conductor damage thanks to automatic adjustment to the conductor cross-section. They are used for single-, multi- or fine-wire conductors with PVC insulation and for thin ribbon cables.

Sicherheitswerkzeuge.png

Better safe than sorry.
Electricians put their faith in their tools daily. Electricity is always a potential hazard. Whether they are cutting cables to size, fitting socket outlets or configuring switch cabinets, they need tools they can rely on without fail. When an electrician picks up a set of VDE tools made by NWS, he or she is handling quality tools subjected to stringent testing for practical, hands-on applications in electrical jobs. This is, after all, what professional working, health & safety are all about.

nws_i_1000V.png

Safety testing method according to IEC 60900
• Visual check and check of measurements: single check of the lettering on the basis tool as well as on the insulation.
• Check of resistance under hot and cold conditions: under normal temperatures of the surroundings (23° C) as well as under low temperatures (-25° C) on three different positions easy to hurt.
• Single voltage check: check of the electrical insulating characteristics by putting on a 10 KV voltage in a water bath for three minutes and measuring the deflecting electricity.
• Pressure check - check of puncture: storage of tools in a warming box for 2 hours at the temperature of 70° C putting on a 5 KV Voltage for three minutes and raising a power of 20 N on the insulation.
• Check of the adhesive power of the insulation: storage of tools in a warming box for 168 h at a temperature of 70° C raising a power of 500 N for three minutes on the area between the conductive part and the insulation.
• Check of fire risk: raising a flame on the insulation for 10 seconds.