End-Sleeves
- For establishing solderless, electrical connections according to DIN
- Surface galvanically tin-plated
- Material made of Cu (copper)
Article | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
144-0,25-5 | 5 | 0,25 | 23 | DIN 46228, Teil 1 | 20 | 1000 | 40 03758 14400 8 | |||
144-0,25-7 | 7 | 0,25 | 23 | DIN 46228, Teil 1 | 30 | 1000 | 40 03758 14402 2 | |||
144-0,34-5 | 5 | 0,34 | 22 | DIN 46228, Teil 1 | 20 | 1000 | 40 03758 14403 9 | |||
144-0,34-7 | 7 | 0,34 | 22 | DIN 46228, Teil 1 | 30 | 1000 | 40 03758 14404 6 | |||
144-0,5-6 | 6 | 0,5 | 20 | DIN 46228, Teil 1 | 30 | 1000 | 40 03758 14464 0 | |||
144-0,5-8 | 8 | 0,5 | 20 | DIN 46228, Teil 1 | 40 | 1000 | 40 03758 14408 4 | |||
144-0,5-10 | 10 | 0,5 | 20 | DIN 46228, Teil 1 | 50 | 1000 | 40 03758 14406 0 | |||
144-0,75-6 | 6 | 0,75 | 18 | DIN 46228, Teil 1 | 35 | 1000 | 40 03758 14465 7 | |||
144-0,75-8 | 8 | 0,75 | 18 | DIN 46228, Teil 1 | 50 | 1000 | 40 03758 14469 5 | |||
144-0,75-10 | 10 | 0,75 | 18 | DIN 46228, Teil 1 | 60 | 1000 | 40 03758 14409 1 | |||
144-1,0-6 | 6 | 1 | 17 | DIN 46228, Teil 1 | 45 | 1000 | 40 03758 14466 4 | |||
144-1,0-8 | 8 | 1 | 17 | DIN 46228, Teil 1 | 55 | 1000 | 40 03758 14411 4 | |||
144-1,0-10 | 10 | 1 | 17 | DIN 46228, Teil 1 | 70 | 1000 | 40 03758 14490 9 | |||
144-1,5-7 | 7 | 1,5 | 15 | DIN 46228, Teil 1 | 65 | 1000 | 40 03758 14467 1 | |||
144-1,5-10 | 10 | 1,5 | 15 | DIN 46228, Teil 1 | 90 | 1000 | 40 03758 14491 6 | |||
144-1,5-12 | 12 | 1,5 | 15 | DIN 46228, Teil 1 | 105 | 1000 | 40 03758 14412 1 | |||
144-1,5-18 | 18 | 1,5 | 15 | DIN 46228, Teil 1 | 155 | 1000 | 40 03758 14413 8 | |||
144-2,5-7 | 7 | 2,5 | 13 | DIN 46228, Teil 1 | 75 | 1000 | 40 03758 14468 8 | |||
144-2,5-10 | 10 | 2,5 | 13 | DIN 46228, Teil 1 | 110 | 1000 | 40 03758 14418 3 | |||
144-2,5-12 | 12 | 2,5 | 13 | DIN 46228, Teil 1 | 130 | 1000 | 40 03758 14493 0 | |||
144-2,5-18 | 18 | 2,5 | 13 | DIN 46228, Teil 1 | 200 | 1000 | 40 03758 14419 0 | |||
144-4,0-9 | 9 | 4 | 11 | DIN 46228, Teil 1 | 160 | 1000 | 40 03758 14307 0 | |||
144-4,0-12 | 12 | 4 | 11 | DIN 46228, Teil 1 | 200 | 1000 | 40 03758 14494 7 | |||
144-4,0-15 | 15 | 4 | 11 | DIN 46228, Teil 1 | 265 | 1000 | 40 03758 14429 9 | |||
144-4,0-18 | 18 | 4 | 11 | DIN 46228, Teil 1 | 320 | 1000 | 40 03758 14439 8 | |||
144-6,0-10 | 10 | 6 | 10 | DIN 46228, Teil 1 | 60 | 100 | 40 03758 14492 3 | |||
144-6,0-12 | 12 | 6 | 10 | DIN 46228, Teil 1 | 70 | 100 | 40 03758 14495 4 | |||
144-6,0-15 | 15 | 6 | 10 | DIN 46228, Teil 1 | 85 | 100 | 40 03758 14498 5 | |||
144-6,0-18 | 18 | 6 | 10 | DIN 46228, Teil 1 | 105 | 100 | 40 03758 14308 7 | |||
144-10,0-12 | 12 | 10 | 7 | DIN 46228, Teil 1 | 85 | 100 | 40 03758 14496 1 | |||
144-10,0-15 | 15 | 10 | 7 | DIN 46228, Teil 1 | 105 | 100 | 40 03758 14499 2 | |||
144-10,0-18 | 18 | 10 | 7 | DIN 46228, Teil 1 | 125 | 100 | 40 03758 14462 6 | |||
144-16,0-12 | 12 | 16 | 5 | DIN 46228, Teil 1 | 105 | 100 | 40 03758 14497 8 | |||
144-16,0-15 | 15 | 16 | 5 | DIN 46228, Teil 1 | 135 | 100 | 40 03758 14461 9 | |||
144-16,0-18 | 18 | 16 | 5 | DIN 46228, Teil 1 | 150 | 100 | 40 03758 14463 3 | |||
144-16,0-25 | 25 | 16 | 5 | DIN 46228, Teil 1 | 220 | 100 | 40 03758 14414 5 | |||
144-16,0-32 | 32 | 16 | 5 | DIN 46228, Teil 1 | 280 | 100 | 40 03758 14417 6 | |||
144-25,0-15 | 15 | 25 | 3 | DIN 46228, Teil 1 | 250 | 50 | 40 03758 14420 6 | |||
144-25,0-18 | 18 | 25 | 3 | DIN 46228, Teil 1 | 295 | 50 | 40 03758 14421 3 | |||
144-25,0-25 | 25 | 25 | 3 | DIN 46228, Teil 1 | 410 | 50 | 40 03758 14422 0 | |||
144-25,0-32 | 32 | 25 | 3 | DIN 46228, Teil 1 | 520 | 50 | 40 03758 14423 7 | |||
144-35,0-18 | 18 | 35 | 2 | DIN 46228, Teil 1 | 135 | 50 | 40 03758 14424 4 | |||
144-35,0-25 | 25 | 35 | 2 | DIN 46228, Teil 1 | 180 | 50 | 40 03758 14427 5 | |||
144-35,0-32 | 32 | 35 | 2 | DIN 46228, Teil 1 | 235 | 50 | 40 03758 14428 2 | |||
144-50,0-18 | 18 | 50 | 0 | DIN 46228, Teil 1 | 170 | 50 | 40 03758 14441 1 | |||
144-50,0-25 | 25 | 50 | 0 | DIN 46228, Teil 1 | 235 | 50 | 40 03758 14443 5 | |||
144-50,0-32 | 32 | 50 | 0 | DIN 46228, Teil 1 | 295 | 50 | 40 03758 14444 2 |
Crimp material
All cable connectors and terminal sleeves are temperature-resistant up to 105 °C and are available in special sizes in addition to the standard ones on request.
Connecting to the future
Solar energy is a clean alternative source of electricity. To make sure it is also a safe source, junction box and switch cabinet wiring has to be properly stripped, crimped and connected up. Using NWS wire stripping and crimping tools, electricians can handle wires and cables in line with all the applicable regulations and down to the millimetre. In this way, whether private houses, factory roofs or photovoltaic installations, they all become clean and safe players in the transition to renewable energy sources.