Insulated End-Sleeves
- For establishing solderless, electrical connections according to DIN
- Surface galvanically tin-plated
- Material made of Cu (copper)
- Insulated, halogen-free and temperature resistant up to 105°C
- Insulation sleeve made of PP (Polypropylene)
Article |
|
|
|
|
|
|
|
|
|
|
|
---|---|---|---|---|---|---|---|---|---|---|---|
144I-0,25-6 | 12 |
|
6 | 6 | 0,25 | 23 | DIN 46228, Teil 4 | 45 | 1000 | 40 03758 14445 9 | |
144I-0,25-8 | 14 |
|
8 | 6 | 0,25 | 23 | DIN 46228, Teil 4 | 50 | 1000 | 40 03758 14446 6 | |
144I-0,34-6 | 12 |
|
6 | 6 | 0,34 | 22 | DIN 46228, Teil 4 | 45 | 1000 | 40 03758 14448 0 | |
144I-0,34-8 | 14 |
|
8 | 6 | 0,34 | 22 | DIN 46228, Teil 4 | 50 | 1000 | 40 03758 14449 7 | |
144I-0,5-6 | 12 |
|
6 | 6 | 0,5 | 20 | DIN 46228, Teil 4 | 70 | 1000 | 40 03758 14453 4 | |
144I-0,5-8 | 14 |
|
8 | 6 | 0,5 | 20 | DIN 46228, Teil 4 | 70 | 1000 | 40 03758 14470 1 | |
144I-0,5-10 | 16 |
|
10 | 6 | 0,5 | 20 | DIN 46228, Teil 4 | 85 | 1000 | 40 03758 14452 7 | |
144I-0,75-6 | 12 |
|
6 | 6 | 0,75 | 18 | DIN 46228, Teil 4 | 80 | 1000 | 40 03758 14459 6 | |
144I-0,75-8 | 14 |
|
8 | 6 | 0,75 | 18 | DIN 46228, Teil 4 | 80 | 1000 | 40 03758 14471 8 | |
144I-0,75-10 | 16 |
|
10 | 6 | 0,75 | 18 | DIN 46228, Teil 4 | 100 | 1000 | 40 03758 14454 1 | |
144I-0,75-12 | 18 |
|
12 | 6 | 0,75 | 18 | DIN 46228, Teil 4 | 105 | 1000 | 40 03758 14458 9 | |
144I-1,0-6 | 12 |
|
6 | 6 | 1 | 17 | DIN 46228, Teil 4 | 90 | 1000 | 40 03758 14480 0 | |
144I-1,0-8 | 14 |
|
8 | 6 | 1 | 17 | DIN 46228, Teil 4 | 100 | 1000 | 40 03758 14472 5 | |
144I-1,0-10 | 16 |
|
10 | 6 | 1 | 17 | DIN 46228, Teil 4 | 120 | 1000 | 40 03758 14447 3 | |
144I-1,0-12 | 18 |
|
12 | 6 | 1 | 17 | DIN 46228, Teil 4 | 125 | 1000 | 40 03758 14479 4 | |
144I-1,5-8 | 14 |
|
8 | 6 | 1,5 | 15 | DIN 46228, Teil 4 | 110 | 1000 | 40 03758 14473 2 | |
144I-1,5-10 | 16 |
|
10 | 6 | 1,5 | 15 | DIN 46228, Teil 4 | 130 | 1000 | 40 03758 14481 7 | |
144I-1,5-12 | 18 |
|
12 | 6 | 1,5 | 15 | DIN 46228, Teil 4 | 150 | 1000 | 40 03758 14482 4 | |
144I-1,5-18 | 24 |
|
18 | 6 | 1,5 | 15 | DIN 46228, Teil 4 | 190 | 1000 | 40 03758 14483 1 | |
144I-2,5-8 | 14 |
|
8 | 6 | 2,5 | 13 | DIN 46228, Teil 4 | 150 | 1000 | 40 03758 14474 9 | |
144I-2,5-12 | 18 |
|
12 | 6 | 2,5 | 13 | DIN 46228, Teil 4 | 200 | 1000 | 40 03758 14486 2 | |
144I-2,5-18 | 24 |
|
18 | 6 | 2,5 | 13 | DIN 46228, Teil 4 | 250 | 1000 | 40 03758 14487 9 | |
144I-4,0-10 | 17 |
|
10 | 7 | 4 | 11 | DIN 46228, Teil 4 | 210 | 100 | 40 03758 14475 6 | |
144I-4,0-12 | 20 |
|
12 | 8 | 4 | 11 | DIN 46228, Teil 4 | 250 | 100 | 40 03758 14354 4 | |
144I-4,0-18 | 26 |
|
18 | 8 | 4 | 11 | DIN 46228, Teil 4 | 320 | 100 | 40 03758 14355 1 | |
144I-6,0-12 | 20 |
|
12 | 8 | 6 | 10 | DIN 46228, Teil 4 | 350 | 100 | 40 03758 14476 3 | |
144I-6,0-18 | 26 |
|
18 | 8 | 6 | 10 | DIN 46228, Teil 4 | 460 | 100 | 40 03758 14358 2 | |
144I-10,0-12 | 22 |
|
12 | 10 | 10 | 7 | DIN 46228, Teil 4 | 450 | 100 | 40 03758 14477 0 | |
144I-10,0-18 | 28 |
|
18 | 10 | 10 | 7 | DIN 46228, Teil 4 | 650 | 100 | 40 03758 14484 8 | |
144I-16,0-12 | 24 |
|
12 | 12 | 16 | 5 | DIN 46228, Teil 4 | 650 | 100 | 40 03758 14478 7 | |
144I-16,0-18 | 28 |
|
18 | 10 | 16 | 5 | DIN 46228, Teil 4 | 800 | 100 | 40 03758 14485 5 | |
144I-25,0-16 | 30 |
|
16 | 14 | 25 | 3 | DIN 46228, Teil 4 | 1600 | 50 | 40 03758 14488 6 | |
144I-25,0-18 | 32 |
|
18 | 14 | 25 | 3 | DIN 46228, Teil 4 | 1700 | 50 | 40 03758 14489 3 | |
144I-25,0-22 | 36 |
|
22 | 14 | 25 | 3 | DIN 46228, Teil 4 | 2000 | 50 | 40 03758 14350 6 | |
144I-35,0-16 | 30 |
|
16 | 14 | 35 | 2 | DIN 46228, Teil 4 | 1900 | 50 | 40 03758 14351 3 | |
144I-35,0-18 | 32 |
|
18 | 14 | 35 | 2 | DIN 46228, Teil 4 | 2100 | 50 | 40 03758 14352 0 | |
144I-35,0-25 | 39 |
|
25 | 14 | 35 | 2 | DIN 46228, Teil 4 | 2500 | 50 | 40 03758 14353 7 | |
144I-50,0-20 | 36 |
|
20 | 16 | 50 | 0 | DIN 46228, Teil 4 | 3300 | 50 | 40 03758 14356 8 | |
144I-50,0-25 | 40 |
|
25 | 15 | 50 | 0 | DIN 46228, Teil 4 | 3600 | 50 | 40 03758 14357 5 |
Crimp material
All cable connectors and terminal sleeves are temperature-resistant up to 105 °C and are available in special sizes in addition to the standard ones on request.
Connecting to the future
Solar energy is a clean alternative source of electricity. To make sure it is also a safe source, junction box and switch cabinet wiring has to be properly stripped, crimped and connected up. Using NWS wire stripping and crimping tools, electricians can handle wires and cables in line with all the applicable regulations and down to the millimetre. In this way, whether private houses, factory roofs or photovoltaic installations, they all become clean and safe players in the transition to renewable energy sources.