Socket Wrenches 1/2" 1000V

  • For allen keys
  • With groves inside for holding set appliances on the tools
  • Multi-layered insulation according to DIN EN/IEC 60900
  • Made of chrome vanadium steel, forged, oil-hardened
  • Base tool chromium-plated
Grouped product items
Article    
2013-8 40 1/2 8 DIN 7448 1000V Design 65 1 40 03758 20008 7  
2013-9 40 1/2 9 DIN 7448 1000V Design 65 1 40 03758 20009 4  
2013-10 40 1/2 10 DIN 7448 1000V Design 70 1 40 03758 20010 0  
2013-11 40 1/2 11 DIN 7448 1000V Design 75 1 40 03758 20040 7  
2013-12 40 1/2 12 DIN 7448 1000V Design 75 1 40 03758 20041 4  
2013-13 40 1/2 13 DIN 7448 1000V Design 75 1 40 03758 20013 1  
2013-14 40 1/2 14 DIN 7448 1000V Design 80 1 40 03758 20014 8  
2013-15 40 1/2 15 DIN 7448 1000V Design 80 1 40 03758 20015 5  
2013-16 40 1/2 16 DIN 7448 1000V Design 85 1 40 03758 20016 2  
2013-17 40 1/2 17 DIN 7448 1000V Design 90 1 40 03758 20017 9  
2013-18 40 1/2 18 DIN 7448 1000V Design 90 1 40 03758 20018 6  
2013-19 40 1/2 19 DIN 7448 1000V Design 100 1 40 03758 20019 3  
2013-20 40 1/2 20 DIN 7448 1000V Design 100 1 40 03758 20020 9  
2013-21 40 1/2 21 DIN 7448 1000V Design 120 1 40 03758 20021 6  
2013-22 40 1/2 22 DIN 7448 1000V Design 120 1 40 03758 20022 3  
2013-23 40 1/2 23 DIN 7448 1000V Design 125 1 40 03758 20023 0  
2013-24 40 1/2 24 DIN 7448 1000V Design 140 1 40 03758 20024 7  
2013-26 45 1/2 26 DIN 7448 1000V Design 175 1 40 03758 20026 1  
2013-27 45 1/2 27 DIN 7448 1000V Design 185 1 40 03758 20027 8  
2013-28 45 1/2 28 DIN 7448 1000V Design 190 1 40 03758 20028 5  
2013-30 45 1/2 30 DIN 7448 1000V Design 230 1 40 03758 20030 8  
2013-32 47 1/2 32 DIN 7448 1000V Design 280 1 40 03758 20032 2  
Loading...
nws_i_elektrische-spannung.png

For working at or close to electrical parts please observe safety regulations for electrical works and additional national safety regulations.
Check that insulation is not damaged each time before using the tools. Do not use damaged tools anymore. Keep your safety tools clean and dry. Ensure that the workplace where you are working on live equipment is clean and tidy. Use protective clothing and safety equipment (eg. safety gloves, cover clothes and safety sleeves), especially when working in narrow areas.
Electrical work (worked carried out on electrical devices an systems) must be either conducted by a qualified electrician or supervised and checked by one.

Spanners and Ratchets
Our spanners and ratchets, made of chrome vanadium steel or another equally high-quality tool steel, feature multilayer insulation in compliance with IEC 60900. After all, this is the only way to ensure your safety when you have to work on live parts without danger.

Sicherheitswerkzeuge.png

Better safe than sorry.
Electricians put their faith in their tools daily. Electricity is always a potential hazard. Whether they are cutting cables to size, fitting socket outlets or configuring switch cabinets, they need tools they can rely on without fail. When an electrician picks up a set of VDE tools made by NWS, he or she is handling quality tools subjected to stringent testing for practical, hands-on applications in electrical jobs. This is, after all, what professional working, health & safety are all about.

nws_i_1000V.png

Safety testing method according to IEC 60900
• Visual check and check of measurements: single check of the lettering on the basis tool as well as on the insulation.
• Check of resistance under hot and cold conditions: under normal temperatures of the surroundings (23° C) as well as under low temperatures (-25° C) on three different positions easy to hurt.
• Single voltage check: check of the electrical insulating characteristics by putting on a 10 KV voltage in a water bath for three minutes and measuring the deflecting electricity.
• Pressure check - check of puncture: storage of tools in a warming box for 2 hours at the temperature of 70° C putting on a 5 KV Voltage for three minutes and raising a power of 20 N on the insulation.
• Check of the adhesive power of the insulation: storage of tools in a warming box for 168 h at a temperature of 70° C raising a power of 500 N for three minutes on the area between the conductive part and the insulation.
• Check of fire risk: raising a flame on the insulation for 10 seconds.